Tilmaamayaasha iyo Meterka Tamarta
Nooca Sharaxaada
Nooca | Shayga | Habka muujinta | Awood | Quful kali ah | Xidhiidh labanlaab ah oo xidhan | Geli | Nafta | Cabirka | Cabbirka goynta | Sawirka | |
hubi | xiriir | hubi | |||||||||
Nooca la dhisay | GPXN-Q | Furaha-riix | - | 96×48×88 | 91×44 | 3 | |||||
GPXN-T | Furaha-riix | 96×48×55 | 91×44 | 3 | |||||||
Swg. | GPXN1-Q | Iftiin | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN1-T | Iftiin | - | 96×48×55 | 91×44 | 1 | ||||||
GPXN4-Q | Furaha-riix | - | - | 144×48×104 | 138×44 | 4 | |||||
GPXN4-T | Furaha-riix | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN5-Q | Furaha-riix | - | - | 96×48×88 | 91×44 | 2 | |||||
GPXN5-T | Furaha-riix | - | 96×48×55 | 91×44 | 2 | ||||||
Hal Insulator oo leh 2 Tilmaamayaal | GPXN4-Q/M | Furaha-riix | - | - | 144×48×104 | 138×44 | 4 | ||||
GPXN4-T/M | Furaha-riix | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN4-T/Z | Furaha-riix | 144×48×104 | 138×44 | 4 | |||||||
Nooca Gaarka ah | GPXN1-Q/CS | Iftiin | - | - | - | 96×48×88 | 91×44 | ||||
GPXNP1-Q/W | Iftiin | - | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN-Q/LCS | Iftiin | - | - | 96×48×88 | 91×44 | 3 |
Tusiyaha Voltage-ka ee Lagu Isticmaalay Unuga Weyn ee Giraan
Tilmaamaha korantada waxaa lala isticmaalaa dahaye si loo muujiyo xaaladda korantada ee wareegga korantada.
Qalabka korantada ee joogtada ah GPXN9-C waxaa loo adeegsadaa tilmaame si loo muujiyo xaaladda koronto.Fogaanta daloolka ee terminaalka-hubinta korontadu waa 14mm ama 19mm.
Isbarbardhigga wejiga GPXN-C waxaa loo adeegsadaa tilmaame si uu u muujiyo xaaladda koronto ee wareegga korantada sare iyo hubinta isku xigxiga qalabka korontada.
Hubinta awoodda: isbarbardhigga wejiga gelinta dhulka ama meelaha kale ee qalabka korantada sare.
Marxaladda hubinta: isbarbardhigga wejiga geli isla wejiga korantada hubinta labada qalab ee korantada sare leh, haddii nalka LED uu ifayo, waxay tusinaysaa in marxaladda imtixaanku leeyahay koronto.
Tusiyaha booska
Tusiyaha boosku waxa uu la jaanqaadi karaa booska shaqada iyo xaaladda aaladaha beddelka sida beddelka iyo jebiya nidaamka korontada.Waxaa si aad ah loo isticmaalaa dhammaan noocyada guddiga jilitaanka ee qolka kontoroolka dhexe iyo guddiga beddelka ee warshadda korantada, saldhigga korantada iyo xarunta beddelka.Tilmaamayaasha boosaska taxanaha ah waxay leeyihiin isku hallayn sare, kala duwanaansho shaqo oo ballaadhan iyo cimri dherer.DC iyo AC ayaa diyaar u ah isticmaalka.
Qiyaasaha Farsamada
danab la qiimeeyay | DC/AC 98V~242V |
Xoogga iftiinka | 40 cd/㎡ |
Inta jeer ee korontadu waxay u adkeysan kartaa danab | 2kV/1 daq |
Iska caabin dahaarka | ≥100MΩ |
Awood darida | ≤1W |
Heerkulka shaqada | -15 ℃ ilaa +50 ℃ |
Nolosha qofka | >10 sano |
Muujinta shaqada | Xaalada shaqada waxaa lagu muujiyay midab casaan/cagaaran iyo sawiro(sida ikhtiyaarka macaamiisha) |
Cabbirka dulucda: | 37.5×37.5×62(mm) |
Cabbirka goynta: | Φ25 (mm) |
Qaabka | Sharaxaada |
GPWZ25-K/2 | Tusiyaha booska-wareeg-jabiye |
GPWZ25-E/1 | Tusiyaha booska-Beddelka Dhulka |
GPWZ25-B/2 | Tusiyaha Booska-Gaadiidka Gacanta ku haya |
GPWZ25-B/1 | Tusiyaha booska-isku-xidhaha |
GPWZ25-K/1 | Tilmaamaha booska-Saddexda boos beddelka |
Booska Muujinaya Shaashada GPAS-72
GPAS-72 booska taxanaha ah ee tilmaamaya shaashadu waxay qabataa LED sida isha iftiinka, oo leh isticmaalka tamarta yar, kalsoonida sare, nolosha adeegga dheer, iwm.Iyada oo leh hawlo badan oo tilmaame-voltage ah, is-dhexgal, heerkulka & xakamaynta qoyaanka, tilmaanta booska gaadhi-gacmeedka, tilmaanta heerka wareegga wareegga, tilmaanta heerka beddelka dhulka, tilmaanta tamarta kaydsan.Waa doorashada wanaagsan in la beddelo tusaha booska gobolka ee hal beddelka ah.
Qiyaasaha Farsamada
danab la qiimeeyay | AC/DC 110V/220V |
Inta jeer ee awoodda u adkeysaneyso | 2kV/daqiiqo |
Deegaanka shaqada | -25 ℃ ilaa 55 ℃, ≤90% RH |
Tilmaamaha Analog iftiinka iftiinka | >40cd/m2 |
Nolosha shaqada | 10 sano |
Heerka ilaalinta | IP42 |
Cabirka | 199x146x63mm |
Cabbirka goynta | 177x121mm |
Tilmaamaha FarsamadaGpj-3100 Taxanaha Wareegga Gaaban iyo Tusiyaha Cilada Dhulka
Taxanaha GPJ-3100 ee wareegga gaaban iyo tusiyaha cilladaha dhulka waxaa loogu talagalay in lagu tijaabiyo laguna muujiyo cilladda wareegga gaaban iyo dhulka waqtiga dhabta ah.Waxaa lagu dabaqaa si loola socdo wareegyada gudaha RMU, khadka sare, khadka qaybinta fiilada korontada, beddelka nooca sanduuqa iyo meelaha kale ee la midka ah.Sida ku cad calaamada alaarmiga ee uu muujiyay tusaha, shaqaaluhu waxay si degdeg ah u garan karaan oo ay u jari karaan aagga cilladda marka wareegga gaaban ama cilada dhulku ay ka dhacdo wareegga wareegga, si nidaamku u soo kabsado koronto-siinta meelaha aan cilladda lahayn si degdeg ah si loo badbaadiyo waqtiga oo loo kordhiyo waxtarka.
Xogta Farsamada
1. wareegga gaaban ee qaylo-dhaanta hadda: 100A ilaa 1000A wakhtiga daahitaanka 40ms
2. Dhulka hadda digniinta leh: 20A,30A,40A,50A,60A±10% daahitaanka wakhtiga 40ms
3. Heerkulka kala duwan: -25 ilaa +70 ℃
4. Xaddiga qoyaanka: ≦95%
5. Dhererka rasaasta dhulka: 4m
6. Samee dhererka fiber indhaha 3.5m
7. Korontada: baytari lithium 3.6V/2.45Ah
8. Wakhtiga dib u habeynta tooska ah: 7s,2s,4hrs,8s
9. Soo gudbinta wax soo saarka: 120 V AC 1A, 30V DC 2A
10.Main kantaroolka cabbirka: 95x50x80mm
11.Goynta godka cabbirka: 91x44 mm
12.Fasalka Ilaalinta : Maamulaha Guud: IP40, Sensor: IP65