12/24/40.5kV Isku-xidhka Shutter-ka iyo Isku-xidhka
Shutter Assembly 5GP.320.010 Rakibaadda Jaantuska
(800mm ballac oo meel dhexe la dhigay)
Golaha Shutter 5GP.320.010 Liiska qabanqaabada
Maya | Magaca | Sawirka no. | Qty.(pc/set) |
1 | Garabka taageerada midig | 8GP.123.011 | 1 |
2 | Saxanka isku xirka saxda ah | 5GP.235.011 | 1 |
3 | Muujinaya sumadda | 8GP.866.014 | 1 |
4 | Xiriirka bidix | 5GP.235.010 | 1 |
5 | garabka taageerada bidix | 8GP.123.010 | 1 |
6 | Alxanka isku xirka | 5GP.174.016.1 (VD4) | 2 |
5GP.174.016.2 (loogu talagalay GPVN) | |||
5GP.174.016.3 (VB2) | |||
7 | Albaabka hoos loo dhigo | 8GP.320.010 | 1 |
8 | Block jaamaysan 8 | DK-8 | 8 |
9 | saxan bracket | 8GP.123.013 | 3 |
Maya | Magaca | Sawirka no. | Qty.(pc/set) |
10 | Alxanka isku xirka | 5GP.174.017.1 (VD4, 40kA) | 2 |
5GP.174.017.2 (VD4, 31.5kA) | |||
5GP.174.017.3 (loogu talagalay GPVN) | |||
5GP.174.017.4 (VB2) | |||
11 | Muujinaya sumadda | 8GP.866.012 | 1 |
12 | Muujinaya sumadda | 8GP.866.013 | 2 |
13 | saxan bracket | 8GP.123.012 | 3 |
14 | Xirmada sare | 8GP.320.011 | 1 |
15 | Usha hagaha | 8GP.234.011 (VD4, GPVN) | 2 |
8GP.234.011.1 (VB2) | |||
16 | Gacan-joojinta | 8GP.210.011 | 2 |
Liiska habaynta xidhidhka kale ee qeexan
Koodhka | 5GP.320.010.1 | 5GP.320.010.2 | 5GP.320.010.3 | 5GP.320.010.4 | 5GP.320.010.5 |
Ballaca golaha | 650mm | 700mm | 840mm | 900mm | 1000mm |
Albaabka sare | 8GP.320.011.1 | 8GP.320.011.2 | 8GP.320.011.3 | 8GP.320.011.4 | 8GP.320.011.5 |
Albaabka hoose | 8GP.320.010.1 | 8GP.320.010.2 | 8GP.320.010.3 | 8GP.320.010.4 | 8GP.320.010.5 |
Golaha Shutter 5GP.320.011
(1000mm ballac oo meel dhexe la dhigay)
Qalabka Shutter Mechanism 5GP.320.011 Liiska qabanqaabada
(1000mm ballac oo meel dhexe la dhigay)
Maya | Magaca | Sawirka no. | Qty.(pc/set) |
1 | Garabka taageerada midig | 8GP.123.276 | 1 |
2 | Saxanka isku xirka saxda ah | 5GP.235.012 | 1 |
3 | Muujinaya sumadda | 8GP.866.014 | 1 |
4 | Saxanka isku xirka bidix | 5GP.235.013 | 1 |
5 | garabka taageerada bidix | 8GP.123.275 | 1 |
6 | Isku xirka alxanka | 5GP.174.281 | 2 |
7 | Xiritaanka hoose | 8GP.320.273 | 1 |
8 | Baloog ayaa la xayiray 10 | DK-10 | 8 |
Maya | Magaca | Sawirka no. | Qty.(pc/set) |
9 | saxan bracket | 8GP.123.278 | 3 |
10 | Isku xirka alxanka | 5GP.174.282 | 2 |
11 | Muujinaya sumadda | 8GP.866.012 | 1 |
12 | Muujinaya sumadda | 8GP.866.013 | 2 |
13 | saxan bracket | 8GP.123.277 | 3 |
14 | Xirmada sare | 8GP.320.274 | 1 |
15 | Usha hagaha | 8GP.234.272 | 2 |
16 | Gacan-joojinta | 8GP.210.011 | 2 |
Liiska habaynta xidhidhka kale ee qeexan
Koodhka | 5GP.320.011.1 | 5GP.320.011/JY | 5GP.320.011.2 | 5GP.320.011.3 |
Ballaca golaha | 800mm | 1000mm (dahaadh) | 1100mm | 1200mm |
Albaabka sare | 8GP.320.274.1 | 5GP.320.275 | 8GP.320.274.2 | 8GP.320.274.3 |
Albaabka hoose | 8GP.320.273.1 | 5GP.320.275.1 | 8GP.320.273.2 | 8GP.320.273.3 |
Fiiro gaar ah: 5GP.320.275 waxaa loogu talagalay dahaadhka dahaadhka ee saxanka SMC ee dhexda ah iyo labadaba ku dhammaada saxan bir ah, shirka kale ee daahyada haddii loo baahdo albaabka dahaarka fadlan sheeg.
Aaladda isku xidhka shaqada ee is-beddelka dhulka (Wixii xiriirinta cududda wadista hawlgalka) 5GP.363.010.1 jaantuska kulanka
Tilmaamaha Qalabka Isku-xidhka
Aaladda qufulka waxaa lagu daraa qufulka gadaale ee albaabka dambe kaas oo loo qaabeeyey iyada oo lagu salaynayo 5GP.363.010 asal ahaan aaladda isku xidhka shaqada ee beddelka dhulka.Taasi waa, ka dib marka dabada dhulku xidho oo fur albaabka danbe (saanadda xidhidhiyaha), xidhidhiyaha asalka ah ayaa weli shaqayn kara beddelka earthing, laakiin tani ma awoodin.Waa in aad marka hore xidhid albaabka danbe (taariikhda wax lagu xidho) si aad u hawl galiso dabada dhulka.
Mabaadi'da shaqada ee qalabka isku-xidhka ayaa beddelaya lambarka 24 ee gacmaha qufulka oo loo beddelo waxa ku tusay midigta iyo guga lagu daray iyadoo lagu saleynayo asalka 5GP .363.010.Markuu albaabka danbe furmo, gacanta qufulku waxa uu galaa dalool labajibbaaran ee golaha wasiirada (xajmiga lagu taliyay 35X35), beddelka dhulku lama shaqayn karo.
Aaladda isku xidhka hawlgalka beddelidda dhulka
5GP.363.010.1 liiska habaynta.
Maya | Magaca | Sawirka no. | Qty.(pc/set) |
1 | Qaadashada | 8GP.263.011 | 1 |
2 | Qaybta | 8GP.192.010 | 1 |
3 | Qaybta | 8GP.192.011 | 1 |
4 | Gacanta dhidibka | 8GP.210.014.1 | 2 |
5 | Qaybta | 8GP.151.041 | 1 |
6 | Gacanta dhidibka | 8GP.211.061 | 1 |
7 | Qaybta | 8GP.151.039 | 1 |
8 | Gacanta dhidibka | 8GP.211.062 | 1 |
9 | Bolt M5×12 | GB70-85 | 1 |
10 | Qaybta | 8GP.151.042 | 1 |
11 | Qaybta | 8GP.151.043 | 1 |
12 | Usha hawlgalka | 8GP.200.013.1 (Log 1432 qoto dheer ee golaha wasiirada 1500 qoto dheer) | 1 |
8GP.200.013.2 (Log 1590 ee qoto dheer golaha wasiirada 1660) | 1 | ||
13 | saxan taageere | 8GP.161.058 | 1 |
8GP.161.058.1 (Doorashada) | 1 |
Maya | Magaca | Sawirka no. | Qty.(pc/set) |
14 | Dabool | 8GP.017.011.1 | 1 |
15 | Bracket | 5GP.043.022 | 1 |
16 | saxan taageere | 8GP.161.059 | 1 |
17 | slider | 8GP.143.010 | 2 |
18 | Gacanta dhidibka | 8GP.211.058 | 1 |
19 | Gacan-joojinta | 8GP.211.057 | 3 |
20 | Saldhigga taageerada | 8GP.043.019 | 1 |
21 | Xir muujinta | 8GP.866.010 | 1 |
22 | Isku xirka usha | 5GP.233.030.1 | 1 |
5GP.233.030.3 (Doorashada) | 1 | ||
23 | Muujin furan | 8GP.866.011 | 1 |
24 | Gacanta quful | 8GP.211.201 | 1 |
25 | Saxanka ilkuhu | 8GP.151.044 | 1 |
26 | Gacanta dhidibka | 8GP.211.060 | 2 |
27 | Tag | 8GP.860.010 | 1 |
28 | guga cadaadiska | 8GP.282.201 | 1 |
29 | Qufulka gacanta ee hagaajinta Bolt | 8GP.920.002 | 1 |
Fiiro gaar ah:
1. No. 1 ~ 12 eeg bogga hore.
2. No. 22 Isku xirka usha isku xirka, cududda isku xirka waxay leedahay laba cabbir: Masaafada Xarunta Golaha 60mm ee caadiga ah.Haddii aad u baahan tahay masaafada dhexe ee 80mm fadlan calaamadee bogga 17 tilmaanta isku xidhka cududda, oo qeex marka aad dalbanayso.
Aaladda isku xidhka shaqada ee dhul-bedelashada (For bevel gear drive operation) 5GP.577.1001
Aaladda isku xidhka hawlgalka beddelidda dhulka (For bevel gear drive operation) 5GP.577.1001 liiska habaynta
Maya | Magaca | Sawirka no. | Qty.(pc/set) |
1 | Qaadashada | 8GP.263.011 | 1 |
2 | saxan joojin | 8GP.151.084 | 2 |
3 | Gacanta dhidibka | 8GP.210.014.1 | 2 |
4 | Qaybta | 8GP.151.041 | 1 |
5 | Gacanta dhidibka | 8GP.210.014.2 | 1 |
6 | Bolt M 5X12 | GB70-85 | 1 |
7 | Qaybta | 8GP.151.042 | 1 |
8 | Qaybta | 8GP.151.043 | 1 |
9 | Gacanta dhidibka | 8GP.210.014.3 | 1 |
Maya | Magaca | Sawirka no. | Qty.(pc/set) |
10 | Gacan-joojinta | 8GP.210.322 | 1 |
11 | Usha hawlgalka | 8GP.174.214 | 1 |
12 | Dabool | 8GP.017.011.2 | 1 |
13 | Saldhigga taageerada | 5GP.043.022 | 1 |
14 | slider | 8GP.143.010 | 2 |
15 | saxan taageere | 8GP.161.059 | 1 |
16 | saxan taageere | 8GP.161.058 | 1 |
17 | Saxanka ilkuhu | 8GP.151.044 | 1 |
18 | Tag | 8GP.860.010 | 1 |
Fiiro gaar ah: 1. Farsamayntan waxay u baahan tahay in lagu xidho albaabka hoose, fadlan sheeg marka aad dalbanayso.