Xaaladda deegaanka
Heerkulka deegaanka: -25℃~+45℃, celceliska maalinlaha ah: ≤35℃
Dhererka: 1000m (Heerka);waxay gaari kartaa ilaa 4500m dalbashada gaarka ah;
Qoyaanka qaraabada: celceliska maalinlaha ah ≤95%, celceliska bishii ≤90%;
Xoogga dhulgariirka ≤8 darajo;
Munaasabadaha lagu dabaqi karo waa inay ka xoroobaan waxyaabaha guban kara, walxaha qarxa, daxalka iyo gariirka daran.
Qaabka
Tilmaamaha alaabta
1) Alaabtani waxay khusaysaa GPVN-12kV/17Kv/24kV oo samaysan ama xidhidhiyaha vacuum circuit breaker ama ABB's VD4 vacuum circuit breaker.
2) Our qaabeynta wax soo saarka xiriiriyaha vacuum GPVC - isku darka fiyuuska ama xiriiriyeyaasha vacuum ee shirkadda ABB, kaas oo ka koobnaan kara FC loop cubicle, si loo daboolo nidaamka korontada ee dhirta korontada iyo baahida shirkadaha kale ee warshadaha iyo macdanta.
3) Isticmaalka saxan bir ah oo aad u fiican oo aluminium-zinc ah oo saxan qalabka CNC ee saxda ah oo lagu soo ururiyey golaha wasiirada, iyo isticmaalka habka laablaabashada labajibaaran, waxay si weyn u wanaajisaa xoogga golaha.
4) Doorka dusha sare ee epoxy resin electrostatic habka buufinta budada, iska caabinta daxalka, oksaydhka, saamaynta iyo adhesion xooggan.
5) Qaab dhismeedka golaha wasiirada oo si buuxda u xidhan ayaa si buuxda loo hubiyaa, unugyadii shaqaynayeyna waa la kala soocay.Marka albaabku xiran yahay, waxay gaari kartaa hawlgalka wareegga wareegga iyo beddelka dhulka.
6) Farsamaynta istaroogga saxda ah, hubi gawaarida is-beddelka wanaagsan.
7)Qorshaha aasaasiga ah ee saxda ah si loo daboolo baahiyaha kala duwan ee isticmaalayaasha, oo awood u siinaya qorshe laba-korley ah.
8) Daar deg deg ah oo loogu talagalay dhul-dhigista iyo wareegyada gaaban, iyo si loo gaaro hawlgalka koronto (Motorized).
9) Hab fudud oo wax ku ool ah "Shanta Badbaadada" habka isku xidhka ayaa si kalsooni leh uga hortagi kara si xun u isticmaalka waxayna hubin kartaa badbaadada hawlwadeenka.
10) Switchgear waxaa iska leh nooca Arc-proof, oo ku yaal qeybta sare ee qeybta baska, qeybta fiilada wareegga wareegga, iyo qeybta teerminalka fiilada waxaa lagu qalabeeyay aaladaha gargaarka cadaadiska.
11) Qaybta fiilada ayaa leh meel bannaan, si fudud ayaa loogu xidhi karaa fiilooyinka badan, oo hubi dhererka rakibidda fiilada.
12) Qiimaynta ilaalinta adag (IP4X), si wax ku ool ah looga hortago arrimaha shisheeye ama duulaanka cayayaanka.
13) Nidaamka labaad ee ikhtiyaariga ah ee raacaya qalabka ilaalinta amniga wuxuu leeyahay shaqo is-aqoonsi ah iyo isgaarsiin xogta, kombiyuutar isku dhafan oo caqli leh, si loo gaaro kontoroolka fog, telemetry fog, daawashada fog, hagaajinta fog.
15
15) Ku gudubtay tijaabooyinka ku habboonaanta korantada ee shaybaarka tijaabada qalabka tamarta sare.
A. Tilmaanta Farsamada ee 12Kv qalabka beddelka
Shayga | Unug | Xogta | |
danab la qiimeeyay | kV | 6 ~ 12 | |
Inta jeer ee la qiimeeyay | Hz | 50/60 | |
Hadda la qiimeeyay | A | 630-4000 | |
Heerka dahaarka la qiimeeyay | 1min inta jeer ee tamarta (Wajiga ilaa dhulka/xidhiidhyada furan) | kV | 42/48 |
Hilaaca hillaaca u adkaysta danab (Wajiga ilaa dhulka/xidhiidhyada furan oo dhan) | kV | 75/85 | |
Basbarka weyn ayaa lagu qiimeeyay hadda | A | 1250,1600,2000,2500,4000 | |
Sub-busbar ayaa lagu qiimeeyay hadda | A | 630,1250,1600,2000,2500,3150 | |
Lagu qiimeeyay waqti gaaban oo u adkeysanaya hadda(4s) | kA | 16,20,25,31.5,40,50 | |
Heerka ugu sarreeya ee u adkeysiga hadda jira | kA | 40,50,63,80,100,125 | |
shahaadada ilaalinta | Lifaaqa IP4X, IP2X (Albaabka VCB waa la furay) | ||
Cabbirka dulucda (ballac/qoto dheer/dherer) | mm | 650(800,1000) /1500(1300,1670,2000) /2300 | |
Miisaanka | kg | 500-1200 |
Sawir qaab dhismeedka cubicle 630A ~ 1250A
Sawir qaab dhismeedka cubicle 1600A ~ 4000A
Miiska cabbirrada farsamada ee B.Main ee 17.5kV qalabka beddelka
Maya | Magaca | Unug | Xogta | |
1 | danab la qiimeeyay | kV | 15/17.5 | |
2 | Heerka dahaarka la qiimeeyay | 1 daqiiqo inta jeer ee korontadu u adkeyso danab (RMS) | kV | 50 |
Iftiinka u adkaysta danabka (ugu sarreeya) | 95 | |||
3 | Hadda la qiimeeyay | A | 630-4000 | |
4 | Lagu qiimeeyay furitaanka wareega gaaban | kA | 50 | |
5 | Inta jeer ee awoodda la qiimeeyay | Hz | 50/60 | |
6 | La qiimeeyay samaynta wareega gaaban ee hadda (ugu sarreysa) | kA | 130 | |
7 | Heerka ugu sarreeya ee u adkeysiga hadda jira | kA | 130 | |
8 | Lagu qiimeeyay adkaysiga wakhtiga gaaban | kA | 50 | |
9 | Nolosha korontada | waqtiyo | 20 | |
10 | Lagu qiimeeyay muddada wareega gaaban ee hadda | s | 4 | |
11 | Nolosha makaanikada ee VCB | waqtiyo | 10000 | |
12 | Heerka ilaalinta ee cubicle | Lifaaqa IP4X, IP2X (Albaabka VCB waa la furay) | ||
13 | Cabbirka dulucda (W*D*H) | mm | 800/1000*1500/1670*2300 | |
14 | Miisaanka | kg | 500-1200 |
C.Qaybta Farsamada ee 24kV qalabka beddelka
Shayga | Unug | Xogta | |
danab la qiimeeyay | kV | 24 | |
Inta jeer ee la qiimeeyay | Hz | 50/60 | |
Hadda la qiimeeyay | A | 630,1250, 1600, 2500, 3150, 4000 | |
Heerka dahaarka la qiimeeyay | 1min inta jeer ee tamarta (wajiga ilaa dhulka/xidhiidhyada furan) | kV |
65 |
Hilaaca hillaaca u adkaysta danab (wajiga ilaa dhulka/xidhiidhyada furan) | kV |
125 | |
Lagu qiimeeyay waqti gaaban oo u adkeysanaya hadda(4s) | kA | 20, 25, 31.5 | |
Heerka ugu sarreeya ee u adkeysiga hadda jira | kA | 50, 63, 80 | |
shahaadada ilaalinta | Lifaaqa: IP4X, albaabku furan yahay: IP2X | ||
Cabbirka dulucda (ballac x qoto dheer x dhererka) | mm | 1000(800)x1820(1500)x2430(2300) | |
Miisaanka | kg | 1200-1500 |
1. Awoodda wareegga gaaban ee CT waa in si gaar ah loo tixgeliyaa;
2. Jaantuska laynka korka ka baxaya waa inuu lahaadaa cubicle dheeraad ah.