ACB iyo MCCB
Soo koobid
GPU1 / 2/3 Taxanaha casriga ah ee hawada caalamiga ah ee casriga ah waxaa loogu talagalay alaabta annagu soo saarno, danab lagu qiimeeyay AC 50/60Hz, 480V(690V), lagu qiimeeyay 200A ~ 6300A hadda, inta badan loo isticmaalo qaybinta awoodda iyo ilaalinta wareegyada awoodda qaybinta network, ka hortagga sahayda korantada iyo qalabka korantada ka qaladka xad-dhaaf ah xad-dhaaf ah,-wareeg gaaban, dhulka cillad, iwmBreaker sidoo kale wuxuu leeyahay shaqo go'doon ah, wuxuu waafaqsan yahay heerka GB 14048.2, IEC 60947-2
Astaamaha
1. Qaab dhismeed is haysta
2. Ma jirto masaafo toosan Badbaadada sare
3. Awoodda sare ee On-Off
4. Nooca casriga ah ee ilaalinta safarka dheeraadka ah ee hadda jira, oo leh isgaarsiin isgaarsiineed, Waxaa lagu xakameyn karaa kooxda kombuyuutarka, hawlo fog oo la ogaaday.
5. Muujinta shaqada ammeter, voltmeter
6. Kor iyo hoos ee soo galaya ma saameyn doonaan waxqabadka alaabta
Qaabka
GPU3 | Xakamaynta wareegga hawada caalamiga ah |
1600 | Qaabka gaashaanka hadda |
4 | 3 3-waji aan calaamadin 4 4-Wejiga |
3M nooca smart controller | Xakamaynta smart Nooca 2M: Bandhig tubbada dhijitaalka ah, hagaajinta badhanka, qaybta 3 oo leh shaqada ilaalinta khaladka dhulka Nooca 3M: Bandhig LCD, hagaajinta badhanka, 3 qayb oo leh shaqada ilaalinta khaladka dhulka Nooca 3H: Bandhig LCD, hagaajinta badhanka iyo xidhiidhka, 3 qayb oo leh shaqada ilaalinta qaladka earthing. |
Jidka fuulista | Nooca la soo baxay Nooc go'an |
Jidka isku xidhka | Fiidiyeyaasha tooska ah ee toosan Xadhkaha hore ee saxan-dambe |
Xulashada qalabyada | Tripper-ka hooseeya Dhexdhexaadinta makaanikada: 2 set ama 3 set jabiye ee kabaal toosan oo xidhan 2 dhigay jabiyaha toosan ama toosan oo isku xidhan fiilo bir ah Booska qufulka "furan" (qufulka) La soo bax 3 boos beddel Transformer-ka wajiga N ee isku xira dibadda |
In=630 | Hadda la qiimeeyay (A) |
Fiiro gaar ah:
1. Smart controller waa nooca M;Dareemida kaalmaynta: 4 kooxood oo xiriir ah, Habka isku xirka waa jiif.
2. Koontaroolaha casriga ah, aaladda sii daynta shunt, korantada dhow, habka wadista mootada iyo socodka korantada ka yar waa in la qeexaa qiimaha danab marka la dalbanayo.
Shaxda Xulashada Farsamada
Nooca | Danab shaqeeya oo lagu qiimeeyay Ue(V) | Dahaarka lagu qiimeeyay danab Ui(V) | Dareen la qiimeeyay oo u adkeysanaya danabka Uimp (V) | Qaabka gaashaanka Inm hadda (A) | Hadda la qiimeeyay Inm (A) | Lambarka wejiga |
GPU1-1250 | AC400 AC690 | AC690, AC1000 | 12000 | 1250 | 200, 400,630, 800,1000, 1250 | 3,4 |
GPU1-2000 | 2000 | 630, 800, 1000, 1250, 1600, 2000 | ||||
GPU1-3200 | 3200 | 2000, 2500, 3600, 4000 | ||||
GPU1-6300 | 6300 | 4000, 5000, 6300 |
Awoodda jebinta wareegga-gaaban | Lagu qiimeeyay waqti gaaban u adkeysanaya Icw (kA)/1s hadda | Waxqabadka hawlgalka | |||||
Lagu qiimeeyay ugu badnaan awooda jabinta wareegga gaaban ee Icu (kA) | Ics (kA) oo lagu qiimeeyay awooda jabinta socodka gaaban ee socda | Nolosha makaanikada (waqtiyo) | Nolosha korontada (waqtiyo) | ||||
400V | 690V | 400V | 690V | 400V | 690V | ||
50 | 42 | 42 | 15000 | 6000 | |||
80 | 50 | 50 | 40 | 50 | 40 | 15000 | 10000 |
100 | 65 | 80 | 50 | 80 | 50 | 12000 | 8000 (5000) |
120 | 75 | 100 | 65 | 100 | 65 | 3000 | 1000 |
GPM11 Case Wareega Jabiya
GPM11Z Smart Molded Case Wareegta jebiye
Soo koobida GPM11/GPM11Z
GPM11 taxane ah oo kiis wareeg ah oo jajabiya ayaa ku habboon AC 50/ 60Hz oo lagu qiimeeyay danab shaqeynaya 400V/630V, lagu qiimeeyay hadda ilaa 800A ee shabakad qaybinta korantada qaybinta wareegga korantada iyo ilaalinta, sahayda korantada iyo qalabka korantada ee ka soo horjeeda culeyska xad-dhaafka ah, korantada yar iyo Halisyada wareegga gaaban, waxay wanaajisaa isku halaynta tamarta korontada marka loo eego xaaladaha isticmaalka caadiga ah kuwaas oo aan si joogta ah u bilaabmin sida beddelka khadka iyo matoorka.Iyo sidoo kale shaqada go'doominta.Waxay la kulmeysaa heerka GB/T 14048.2 iyo IEC 60947-2.
Qaabka
GPM11GPM11Z | Case Wareegga Wareega JebiyeSmart Molded Case Wareegga jebiye |
100 | Qaabka gaashaanka hadda |
H | Awood jabinta wareegga-gaaban:N: Nooca caadiga ah S: Nooca caadiga ah: Nooca jabinta sare |
P | Qaabka loo shaqeeyo: Hawlgalka matoorka: Gacan ku haynta ku shaqayn: Hawlgalka ZDirect (koodi ma jiro) |
2 | Habka ilaalinta Xulashada: ilaalinta qaybinta: ma jiro ilaalin motor ah: 2 |
4 | Marxaladda 2aad: laba weji3: saddex weji4: afar waji |
208 | Habka safarka iyo code-ka agabka gudaha |
In=100 | Hadda la qiimeeyay (A) |
B | 4 Wajiga jabiyaha N waxa uu leeyahay 4 nooc oo kala duwan oo lagu asteeyay sida A, B, C, DA: N wajigu ma rakibi doono tripper hadda, iyo N oo ku xidhan had iyo jeer, oo aan lagu shaqayn 3 waji oo kale. wejiga aan lagu shaqayn 3 waji oo kale.C: Wajiga N waxa lagu rakibay tripper hadda, iyo wejiga N oo lagu shaqeeyo 3 waji oo kale.D: Wajiga N waxa lagu rakibay tripper hadda, iyo wejiga N oo had iyo jeer ku xidhan, Aan lagu shaqayn 3 weji oo kale. |
Q | Habka fiilooyinka: Xadhkaha hore ee saxanka: QRear ee fiilooyinka saxanka: HXargaha nooca Plug-in: R |
Fiiro gaar ah: 1. Habka fiilooyinka: gadaal ee fiilooyinka saxanka (400, 630's 4P iyada oo aan lahayn);fiilooyinka nooca fur-in (4P la'aanteed)
2. Qalabka gudaha ayaa lagu rakibay dhinaca bidix ee jabiyaha.
Shaxda xulashada farsamada ee GPM11Z MCCB
Nooca | Danab shaqeeya oo lagu qiimeeyay Ue(V) | Dahaarka lagu qiimeeyay danab Ui(V) | Dareen la qiimeeyay Uimp (V) | Qaabka gaashaanka Inm hadda (A) | Hadda la qiimeeyay Inm (A) | Lambarka wejiga | Awoodda jebinta wareegga-gaaban | Lagu qiimeeyay in uu u adkaysanayo wakhtiga gaaban ee Icw (kA) 1s | Waxqabadka hawlgalka | ||
Lagu qiimeeyay ugu badnaan awooda jabinta wareegga gaaban ee Icu (kA) | Ics (kA) oo lagu qiimeeyay awooda jabinta socodka gaaban ee socda | Nolosha makaanikada (waqtiyo) | Nolosha Korontada (waqtiyo) | ||||||||
GPM11Z-100 | AC400 | AC690 | AC8000 | 100 | 32,100 | 3,4 | 65 | 50 | 1 | 20000 | 8000 |
GPM11Z-225 | 225 | 225 | 65 | 50 | 2.5 | 20000 | 8000 | ||||
GPM11Z-400 | 400 | 400 | 65 | 50 | 5 | 15000 | 7000 | ||||
GPM11Z-630 | 630 | 630 | 65 | 50 | 8 | 10000 | 7000 |
Shaxda xulashada farsamada ee GPM11 MCCB
Nooca | La qiimeeyay danab shaqaynaya Ue | Danab dahaarka lagu qiimeeyay Ui | Dareenka la qiimeeyay ee u adkeysanaya danabka Uimp | Fasalka qaab-dhismeedka ayaa lagu qiimeeyay hadda Inm A | Hadda lagu qiimeeyay gudaha (A) | Lambarka wejiga | Lagu qiimeeyay ugu badnaan koodhka jebinta wareegga gaaban | Lagu qiimeeyay ugu badnaan gaaban -karti jebinta wareegga | Ics (kA) oo lagu qiimeeyay awooda jabinta socodka gaaban ee socda | Nooca qalabka safarka | Waxqabadka hawlgalka (wakhtiyada) | |
Live | No-Nool | |||||||||||
GPM11-63 | 400,690 | 800, 1000 | 8 | 63 | 10, 16, 20, 25, 32, 40, 50, 63 | 3 | N | 10 | 5 | Kuleylka korantada | 3000 | 7000 |
3,4 | S | 25 | 18 | Kuleylka korantada | ||||||||
3,4 | H | 50 | 35 | Kuleylka korantada | ||||||||
GPM11-100 | 100 | 16, 20, 25, 32, 40, 50, 63, 80, 100 | 3 | N | 35 | 25 | Kuleylka korantada | 3000 | 7000 | |||
3,4 | S | 50 | 35 | Kuleylka korantada | ||||||||
3,4 | H | 65 | 50 | Kuleylka korantada | ||||||||
GPM11-160 | 160 | 100, 125, 140, 160 | 3 | N | 35 | 25 | Kuleylka korantada | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Kuleylka korantada | ||||||||
3,4 | H | 65 | 50 | Kuleylka korantada | ||||||||
GPM11-225 | 225 | 100, 125, 140,160, 180,200, 225 | 3 | N | 35 | 25 | Kuleylka korantada | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Kuleylka korantada | ||||||||
3,4 | H | 65 | 50 | Kuleylka korantada | ||||||||
GPM11-250 | 250 | 100, 125, 140,160, 180,200, 225,250 | 3 | N | 35 | 25 | Kuleylka korantada | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Kuleylka korantada | ||||||||
3,4 | H | 65 | 50 | Kuleylka korantada | ||||||||
GPM11-400 | 400 | 225,250, 315,350, 400 | 3 | N | 35 | 25 | Kuleylka korantada | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Kuleylka korantada | ||||||||
3,4 | H | 65 | 50 | Kuleylka korantada | ||||||||
GPM11-630 | 630 | 400, 500, 630, 630, 700,800 | 3 | N | 35 | 25 | Kuleylka korantada | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Kuleylka korantada | ||||||||
3,4 | H | 65 | 50 | Kuleylka korantada | ||||||||
GPM11-800 | 800 | 630,700, 800 | 3,4 | S | 50 | 35 | Kuleylka korantada | 1000 | 4000 | |||
3,4 | H | 65 | 50 | Kuleylka korantada |