Qaabka
GPVN -12Kv/17.5kV Gudaha AC ee korantada sare ee wareegga wareegga
Tilmaamaha Farsamada
Maya | Shayga | Unug | Xogta | ||||||
1 | danab la qiimeeyay | kV | 7.2 ~ 12 (15/17.5) | ||||||
2 | Inta jeer ee la qiimeeyay | Hz | 50/60 | ||||||
3 | Hadda la qiimeeyay | A | 630,1000,1250 | 1600 | 2000,2500,3150 | 4000 | |||
4 | Lagu qiimeeyay qulqulka wareega wareega gaaban | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
5 | Lagu qiimeeyay samaynta wareega gaaban | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
6 | Lagu qiimeeyay adkaysiga wakhtiga gaaban | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
7 | Heerka ugu sarreeya ee u adkeysiga hadda jira | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
8 | Lagu qiimeeyay ka bixista hadda | kA | 12.6 | 12.6 | 16 | 16 | 20 | ||
9 | Lagu qiimeeyay ka baxsan wejigii hore ee khaldaadka dhulka | kA | 17.4 | 21.7 | 27.4 | 27.4 | 34.7 | 34.7 | 43.5 |
10 | Lagu qiimeeyay wakhtiga jabinta wareega gaaban ee hadda jira | Waqtiyada | 50 | 30 | 30 | 12 | |||
11 | Habka hawlgalka ee la qiimeeyay | O-0.3s-CO-180s-CO | O-180-meeyadii-CO-180-meeyadii-CO | ||||||
12 | La qiimeeyay jebinta hadda ee bangiga hal-abuurka ah | A | 630 | ||||||
13 | La qiimeeyay jabinta hadda ee bangiga capacitor dhabarka iyo dhabarka | A | 400 | ||||||
14 | 1 daq.Inta jeer ee korontadu waxay u adkeysan kartaa danab | kV | Marxaladda wejiga/ dhulka: 42, xiriirrada furan oo dhan:48 | ||||||
15 | Hilaaca hillaaca u adkaysta danab | kV | Marxaladda wejiga/ dhulka: 75, xiriirrada furan oo dhan:85 | ||||||
16 | Nolosha makaanikada | Waqtiyada | 20000 | ||||||
17 | Waqtiga xidhitaanka | ms | ≤75 | ||||||
18 | Waqtiga furitaanka | ms | ≤60 | ||||||
19 | Waqtiga kaydinta korantada ee ku hoos jira danab la qiimeeyay | s | ≤10 |
Tilmaanta cabbirka GPVN-12E
GPVN-24
Tilmaamaha Farsamada
Maya | Shayga | Unug | Xogta | |||
1 | danab la qiimeeyay | kV | 24 | |||
2 | Inta jeer ee la qiimeeyay | Hz | 50/60 | |||
3 | Hadda la qiimeeyay | A | 630 1250 1600 2000 2500 3150 4000 | |||
4 | Lagu qiimeeyay qulqulka wareega wareega gaaban | kA | 20 | 25 | 31.5 | 31.5 |
5 | Lagu qiimeeyay samaynta wareega gaaban | kA | 50 | 63 | 80 | 80 |
6 | Wareegga gaaban ee la qiimeeyay u adkeysanaya hadda(4s) | kA | 20 | 25 | 31.5 | 31.5 |
7 | Heerka ugu sarreeya ee u adkeysiga hadda jira | kA | 50 | 63 | 80 | 80 |
8 | Lagu qiimeeyay hadda jabinta tallaabo ka baxsan | kA |
|
| 12.6 | 12.6 |
9 | Lagu qiimeeyay jebinta hadda ee khaladka dhulka ee ka baxsan wejiga | kA | 17.4 | 21.7 | 27.4 | 27.4 |
10 | Waxaa lagu qiimeeyay waqtiyada jebinta ee wareega-gaaban ee jabinta hadda | Waqtiyada | 50 | |||
11 | Sida loo shaqeeyo |
| O-0.3s-CO-180s-CO | |||
12 | La qiimeeyay jebinta hadda ee bangiga hal-abuurka ah | A | 630 | |||
13 | La qiimeeyay jabinta hadda ee bangiga capacitor-ka ee dhabarka | A | 400 | |||
14 | 1 daq.Inta jeer ee korontadu waxay u adkeysan kartaa danab | kV | 50 | |||
15 | Hilaaca hillaaca u adkaysta danab | kV | 125 | |||
16 | Nolosha makaanikada | Waqtiyada | 20000 | |||
17 | Waqtiga xidhitaanka | ms | 75 | |||
18 | Waqtiga furitaanka | ms | 60 | |||
19 | Waqtiga kaydinta ee ku hoos jira danab lagu qiimeeyay | s | 10 |